Housing: SMC polyester plastic reinforced with glass fiber, color RAL 7038 Diffuser: PC polycarbonate plastic Gasket: silicone Central locking: can be opened/closed using a socket key SW8, hinged lamp cover The light fitting is normally supplied without light sources, socket key screw, two Ex e cable glands M25, two Ex e plugs M25 and with four ring screw M8 (pendant version).
Zone 1, 2, 21, 22
T8 fluorescent lamps in parallel configuration
Central locking
Switch with safety lock; when opening the central lock, all poles of the volt-age supply to the ballast are discon-nected
In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply.
Apparatus category:
II 2GD, IM2
Explosion protection:
Ex d e mb IIC T4 Gb, Ex tb IIIC T80°C Db, Ex d e mb l Mb
Enviroment temperature:
-30 °C ≤ Ta ≤ +50 °C [ATEX] -50 °C ≤ Ta ≤ +40 °C [EAC]
»Prejete podatke bomo uporabljali le za namen povpraševanja. Brez vašega soglasja prejetih podatkov ne bomo hranili, obdelovali ali posredovali tretjim osebam.«