Measuring head type MG-de

Measuring head MG-de is intended for use in explosive atmosfere in industry in Zone 1/21. It measures toxic and explosive gases. Measuring head MG-de consist of Ex e enclosure box with terminals and Ex d enclosure where all the electronics and sensors are.

It is designed to detect a particular gas depending on the type of sensor used.

The measuring head MG-de converts the target gas into current. This electrical parameter is amplified, linearised and converted to 4–20 mA signal and conducted via a connecting cable to an alarm unit (MX7, MX5000, MX6000).

Ex marking:
II 2G Ex db eb IIC T5 Gb,
II 2D Ex tb IIIC T100°C Db

Compliance with Essential Health and Safety Requirements has been assured by compliance with:
EN 60079-0:2018,
EN 60079-1:2014,
EN 60079-7:2015/AC:2018,
EN 60079-31:2014